NOTE:
THESE TERMINALS ARE REDUNDANT
PAGE INPUT CONNECTION. USEFUL
WHEN A MODULAR RJ-11 PLUG AND
CABLE IS NOT SUITABLE.
SET TO
HOST SYSTEM
REQUIREMENTS
TO HOST TELEPHONE
SYSTEM OR PAGING
SYSTEM CONTROLLER
PBX HOST
TELEPHONE
SYSTEM
LOOP START TRUNK PORT
OR DRY LOOPO PAGE PORT
Figure 3-6. AmpliCenter Interconnection to Telephone System or to Controller
Connection to
The page input cord that connects to the PagePac Plus AmpliCenter has a
AmpliCenter
standard 4-wire RJ-11 type plug or leads on the end that connects to the
AmpliCenter. The other end of the cord, depending on the host system,
may have a special 25-pair connector, spade-tip leads, or an RJ-11 type
plug.
The page input cord conductors are usually color-coded and are
connected to the host system as follows.
1. Connect black wire to the paired dry contact control lead ground.
2. Connect yellow wire to the paired dry contact control lead C1.
3. Connect red wire to system ring R.
4. Connect green wire to system tip T.